Model number |
Output ripple |
Current display precision |
Volt display precision |
CC/CV Precision |
Ramp-up and ramp-down |
Over-shoot |
GKD12-800CVC | VPP≤0.5% | ≤10mA | ≤10mV | ≤10mA/10mV | 0~99S | No |
During electrolysis, cations in the electrolyte migrate to the cathode and electrons are reduced at the anode. The anion runs to the anode and loses electrons to be oxidized. Two electrodes were connected in copper sulfate solution and direct current was applied. At this point, copper and hydrogen will be found to precipitate from the plate connected to the cathode of the power supply. If it is a copper anode, copper dissolution and oxygen precipitation occur simultaneously.
The module of the synchronous rectifier high-frequency switching power supply is installed in the parallel cabinet, and is connected with the cathode and anode bus of the foil generator through the output of the bus. Clean appearance, compact structure. High power conversion efficiency, reduce customer use cost. Power supply adopts N + 1 backup mode, which can realize thermal maintenance of the whole machine and ensure continuous production by customers.
(You can also Log in and fill in automatically.)