1. Front panel                                       back panel

Xingtongli-Rectifier-Instructions

1-AC Input Switch (Single Phase-1P, Three Phase-3P) to Control AC Power Supply

2-Time Relay (User Optional), Timing Control

3-Output Voltage Display Header (V)

4-Output Current Display Header (A)

5-Constant Current/Constant Voltage Switch, Select Operating Mode, Not Allowed to Change During Device Operation

6-Power Output Switch (ON/OFF), Control Power Operation or Standby

7-Power Operation Status Indicator Light (Green: Normal Power Operation, Red: Power Failure)

8-Power Output Adjustment Potentiometer

9-Pause Button for Time Relay (Supplementary Time Relay)

10-Reset Button for Time Relay (Supplementary Time Relay)

11/12-Output Terminals (Polarity as Marked on the Power Supply Back Panel, Red for Positive, Black for Negative)

13-AC Input Lines (Single Phase-Three Wire: L-N-PE; Three Phase-Four Wire: A(U)-B(V)-C(W)-PE, or Three Phase-Five Wire: A(U)-B(V)-C(W)-N-PE)

14-Chassis Ground (PE)

15-Remote Control Line Output Terminal (Optional for Remote Control Type)

Local/Remote Control Type (Polarity Reverse)

Xingtongli Rectifier Instructions

1 – Automatic Changeover Time Relay (User Optional), Timed Control

2 – Output Voltage Display Header (V)

3 – Output Current Display Header (A)

4 – Manual Forward/Reverse Switch

5 – Manual/Automatic Changeover Switch

6 – Constant Current/Constant Voltage Switch, Select Operating Mode; Constant Current to Constant Voltage Conversion is not allowed during device operation.

7 – Power Output Switch (ON/OFF), Control Power Supply Operation or Standby

8 – Power Output Adjustment Potentiometer

9 – Start Button for Automatic Changeover Time Relay (Compatible with Time Relay)

10 – AC Input Switch (Single-Phase-1P, Three-Phase-3P), Control AC Power Supply

11 – Reset Button for Automatic Changeover Time Relay (Compatible with Time Relay)

12 – AC Input Lines (Single-Phase Three-Wire: L-N-PE; Three-Phase Four-Wire: A(U)-B(V)-C(W)-PE, or Three-Phase Five-Wire: A(U)-B(V)-C(W)-N-PE)

13 – Chassis Ground (PE)

14, 15 – Output Terminals (Polarity as indicated on the power supply back panel, Red for positive, Black for negative)

16 – External Control Box Lead (Choose between Remote Control Panel and Local Control Panel)

17 – Remote Analog Control Port (Optional: Requires PLC Interface Board for power supply)

18 – Remote MODBUS Control Port (Optional: Choose between Remote Analog Control and Remote MODBUS Control; Remote MODBUS Control requires PLC or Microcontroller Control System for power supply)

19 – Power Supply Status Indicator Light (Green: Normal Power Supply Operation, Red: Power Supply Fault)

20 – Local/Remote Control Switch

Remote Control Type

Xingtongli Rectifier Instructions (2)

1 – Output Voltage Display Header (V)

2 – Audio-Visual Alarm (Optional)

3 – Output Current Display Header (A)

4 – Smart Ammeter (Optional)

5 – Soft Start Time Adjustment (0-100S) (Optional)

6 – Power Supply Status Indicator (Green: Power Supply Normal, Red: Power Supply Fault)

7 – Power Output Adjustment Potentiometer

8 – Constant Current/Constant Voltage Conversion Switch, select the operating mode, not allowed to switch between constant current and constant voltage during operation

9 – Pause Button for Time Relay (Compatible with Time Relay)

10 – Power Output Switch (ON/OFF), controls power supply operation or standby

11 – Reset Button for Time Relay (Compatible with Time Relay)

12 – Time Relay (User Optional), for timing control

13 – Fixed Mounting Plate

 

External Control Reversing Type

 

1 – Output Voltage Display Header (V)

2 – Output Current Display Header (A)

3 – Manual/Automatic Reversing Switch

4 – Constant Current/Constant Voltage Conversion Switch, not allowed to switch between constant current and constant voltage during operation

5 – Manual Forward/Manual Reverse Switch

6 – Power Output Adjustment Potentiometer

7 – Remote Control Aviation Socket

8 – Power Output Switch (ON/OFF), controls power supply operation or standby

9 – Start Button for Multi-stage Time Relay (Compatible with Multi-stage Time Relay)

10 – Power Supply Status Indicator (Green: Normal Operation, Red: Power Supply Fault)

11 – Reset Button for Multi-stage Time Relay (Compatible with Multi-stage Time Relay)

12 – Reversing Multi-stage Time Relay, timed reversing control

13 – Audio-Visual Alarm

14 – Fixed Mounting Plate